Name
Profiled steel plate
Technical purpose of product or process Construction material
General comment on data set Declared or functional unit: 1 metric tonne (1000 kg) of product.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 7850.0 kg/m^3
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system b. Hot rolled section steel: A type of steel produced by hot rolling process, with good strength and toughness. Hot-rolled section steel can be composed of different stress components according to the different needs of the structure and can also be used as a connection between the components. It is widely used in various building structures and engineering structures. The composition is described in below table.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 2.5E+4
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 2.09E+5
  • 0.00343
  • -1.28E+5
Input
  • 4.51E+3
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Input
  • 617
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0.000253
  • 0
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 1E+3
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 175
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.00605
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.322
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 157
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 2.5E+4
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 2.09E+5
  • 0.00343
  • -1.28E+5
Input
  • 47
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 1E+3
  • 0
Input
  • 38.8
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 25.2
  • 0.0000015
  • -31.5
Input
  • 617
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0.000253
  • 0
Input
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 2.5E+4
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 2.09E+5
  • 0.00343
  • -1.28E+5
  • 0.0469
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0.000106
  • 1.1E-11
  • -0.0000905
  • 11.1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 12.7
  • 0.00000107
  • -13.2
  • 0.0000427
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 4.6E-11
  • 0
  • 0.00101
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0.000454
  • 6.22E-10
  • -0.000786
  • 1.31
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 1.51
  • 2.12E-7
  • -1.45
  • 14.2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 16.5
  • 0.00000276
  • -15.8
  • 2.33E+3
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 2.62E+3
  • 0.000186
  • -2.98E+3
  • 0.00224
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0.00000216
  • 0
  • 9.09
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.33E+3
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 2.62E+3
  • 0.000188
  • -2.98E+3
  • 5.2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 6.24
  • 6.89E-7
  • -6.02
  • 1.67E+3
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 1.08E+3
  • 0.0000614
  • -1.35E+3

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Potential Human exposure efficiency relative to U235 (IRP) 1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Potential Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Potential incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND